home *** CD-ROM | disk | FTP | other *** search
- Path: ip200.elp.primenet.com!user
- From: massello@primenet.com (Neill A Massello)
- Newsgroups: comp.dcom.modems
- Subject: Re: Motorola 28.8 x-atlantic trouble (also rel. 4)
- Date: 1 Feb 1996 02:58:00 -0700
- Organization: Pither's Flying Tomatoes, Ltd
- Sender: root@primenet.com
- Distribution: world
- Message-ID: <massello-0102960257480001@ip200.elp.primenet.com>
- References: <pope-2401960132340001@pope.edunet.dk> <ABW992nyN8@infsviaz.msk.su>
- X-Posted-By: ip200.elp.primenet.com
- X-Newsreader: Yet Another NewsWatcher 2.1.8
-
- In article <ABW992nyN8@infsviaz.msk.su>, Vadim@infsviaz.msk.su wrote:
-
- > pope@edunet.dk (Povl H. Pedersen) wrote:
- > >
- > >I just did the ultimate test for the Motorola Power 28.8 modems.
- > >I called the Motorola BBS in the USA.
- > >If V.34 is enabled (even if I limit speed to max. 14400 bps), I get a NO
- > >CARRIER before the negotiation is finished.
- > >If I say V.32bis only, I connect at 14400 bps...
- > >
- > >Now, V.34 should be less sensitive to noise than V.32bis, so I wonder why
- > >this problem is still there. Has been there since flash-RAM version 1.
- > >
- >
- > I had the same problem connecting Motorolas 326x V.34 and ZyXels V.32bis.
- > I believe that's because both V.34 and V.32bis protocols have adaptive
- > features (i.e. before establishing connection they try to evaluate the
- > line quality and choose proper transmission parameters).
- > As a result, while Motorola ("V.34 Auto" Mode) was trying to quess the
- > required protocol, ZyXel made attempts to optimize its parameters and
- > that "duel of intellects" lasted till timeout. When I put Motorola
- > into "V.32bis Auto" mode, all became ok.
- >
- > G. Dragon
-
- The Power 28.8's default settings include a rather short 30 seconds for
- carrier timeout (stored in the S7 register). The value used by Supra, for
- example, is 45 seconds. For comparison, at a setting of 30 seconds, the
- Power will hang up and report NO CARRIER after about five rings. A 60
- second setting will result in a wait for about ten rings.
-
- --
- Neill A Massello
- <massello@primenet.com>
- <73324.2047@compuserve.com>