home *** CD-ROM | disk | FTP | other *** search
/ NetNews Offline 2 / NetNews Offline Volume 2.iso / news / comp / dcom / modems-part1 / 3522 < prev    next >
Encoding:
Internet Message Format  |  1996-08-05  |  2.0 KB

  1. Path: ip200.elp.primenet.com!user
  2. From: massello@primenet.com (Neill A Massello)
  3. Newsgroups: comp.dcom.modems
  4. Subject: Re: Motorola 28.8 x-atlantic trouble (also rel. 4)
  5. Date: 1 Feb 1996 02:58:00 -0700
  6. Organization: Pither's Flying Tomatoes, Ltd
  7. Sender: root@primenet.com
  8. Distribution: world
  9. Message-ID: <massello-0102960257480001@ip200.elp.primenet.com>
  10. References: <pope-2401960132340001@pope.edunet.dk> <ABW992nyN8@infsviaz.msk.su>
  11. X-Posted-By: ip200.elp.primenet.com
  12. X-Newsreader: Yet Another NewsWatcher 2.1.8
  13.  
  14. In article <ABW992nyN8@infsviaz.msk.su>, Vadim@infsviaz.msk.su wrote:
  15.  
  16. > pope@edunet.dk (Povl H. Pedersen) wrote:
  17. > >
  18. > >I just did the ultimate test for the Motorola Power 28.8 modems.
  19. > >I called the Motorola BBS in the USA.
  20. > >If V.34 is enabled (even if I limit speed to max. 14400 bps), I get a NO
  21. > >CARRIER before the negotiation is finished.
  22. > >If I say V.32bis only, I connect at 14400 bps...
  23. > >
  24. > >Now, V.34 should be less sensitive to noise than V.32bis, so I wonder why
  25. > >this problem is still there. Has been there since flash-RAM version 1.
  26. > >
  27. > I had the same problem connecting Motorolas 326x V.34 and ZyXels V.32bis.
  28. > I believe that's because both V.34 and V.32bis protocols have adaptive
  29. > features (i.e. before establishing connection they try to evaluate the
  30. > line quality and choose proper transmission parameters).
  31. > As a result, while Motorola ("V.34 Auto" Mode) was trying to quess the
  32. > required protocol, ZyXel made attempts to optimize its parameters and
  33. > that "duel of intellects" lasted till timeout. When I put Motorola
  34. > into "V.32bis Auto" mode, all became ok.
  35. > G. Dragon
  36.  
  37. The Power 28.8's default settings include a rather short 30 seconds for
  38. carrier timeout (stored in the S7 register). The value used by Supra, for
  39. example, is 45 seconds. For comparison, at a setting of 30 seconds, the
  40. Power will hang up and report NO CARRIER after about five rings. A 60
  41. second setting will result in a wait for about ten rings.
  42.  
  43. -- 
  44. Neill A Massello 
  45.   <massello@primenet.com>
  46.   <73324.2047@compuserve.com>
  47.   <massello@eworld.com>
  48.